Evacuated Blood Collection Tube
Introduction of

Ampulab is manufactured and sterilized as same facility through cutting-edge process technology.
system is designated for quick, safe, correct and hygienic blood collection without further handling requirements through user-friendly vacuum system.
The system is composed of sterilized vacuum tube, holder and multi sample needle to eliminate any possible risk while collection blood from patients.
As the essential device for pre-analytic sample collection device, Ampulab system will offer users reliable result from the primary step for every analyzer.
Product Type

Serum Plain Tube
Features of Products
AMPULAB Serum tubes are coated with silicone and micronized silica
particles to accelerate activate the coagulation process with 8~10 times
gentle inversion for serum determinations in chemistry. Specially developed
components on the wall make serum tubes reduce adherence of red blood
cells to tube wall.
Samples processed in these tubes may also be used for routine blood
screening, immunohematology, and diagnostic testing of serum for
infectious disease.
Code | Vol(ml) | Size(mm) | Additives | Packing Q'ty |
---|---|---|---|---|
104101 | 4 | 13 x 75 | Clot Activator | 1,000pcs/Box |
106201 | 6 | 13 x 100 | Clot Activator | 1,000pcs/Box |
100301 | 10 | 16 x 100 | Clot Activator | 1,000pcs/Box |

SSGT (Serum Seperation Gel Tube)
Features of Products
AMPULAB Serum with Gel contains a barrier polymer in the base of the tube and this material causes it to move upward to the serum–clot interface forming a stable separation barrier during centrifugation. Serum may be aspirated directly from the collection tube eliminating the need for manual transfer to another container. In the primary tube and under recommended laboratory conditions, certain parameters remain stable for up to 48 hours.
Code | Vol(ml) | Size(mm) | Additives | Packing Q'ty |
---|---|---|---|---|
103102 | 3.5 | 13 x 75 | Gel / Clot Activator | 1,000pcs/Box |
105202 | 5 | 13 x 100 | Gel / Clot Activator | 1,000pcs/Box |
108302 | 8.5 | 16 x 100 | Gel / Clot Activator | 1,000pcs/Box |

EDTA Tube
Features of Products
AMPULAB EDTA Tubes are coated with K2-EDTA or K3-EDTA for blocking coagulation cascade by binding calcium ions in the blood sample. EDTA tubes must be inverted 8~10 times to assure complete mixing with blood for correct coagulation value. EDTA tubes are used for direct sampling analysis since erythrocytes and leucocytes are stable for 24 hours with EDTA while thrombocytes are stable for 6~8 hours. Blood smearing should be done within 3 hours after blood collection. EDTA tubes are for examination of whole blood in hematology
Code | Vol(ml) | Size(mm) | Additives | Packing Q'ty |
---|---|---|---|---|
201103 | 1 | 13 x 75 | K2-EDTA 1.8mg | 1,000pcs/Box |
202103 | 2 | 13 x 75 | K2-EDTA 3.6mg | 1,000pcs/Box |
203103 | 3 | 13 x 75 | K2-EDTA 5.4mg | 1,000pcs/Box |
204103 | 4 | 13 x 75 | K2-EDTA 7.2mg | 1,000pcs/Box |
206203 | 6 | 13 x 100 | K2-EDTA 10.8mg | 1,000pcs/Box |
200303 | 10 | 16 x 100 | K2-EDTA 18.0mg | 1,000pcs/Box |
201104 | 1 | 13 x 75 | K3-EDTA 1.8mg | 1,000pcs/Box |
202104 | 2 | 13 x 75 | K3-EDTA 3.6mg | 1,000pcs/Box |
203104 | 3 | 13 x 75 | K3-EDTA 5.4mg | 1,000pcs/Box |
204104 | 4 | 13 x 75 | K3-EDTA 7.2mg | 1,000pcs/Box |
206204 | 6 | 13 x 100 | K3-EDTA 10.8mg | 1,000pcs/Box |
200304 | 10 | 16 x 100 | K3-EDTA 18.0mg | 1,000pcs/Box |

Coagulation Tube (Double Layer Tube)
Features of Products
AMPULAB Coagulation tubes are used for examination of coagulation
parameters.
Coagulation tubes contain a buffered sodium citrate solution. It is available
with a citrate concentration of 0.109 mol/l (3.2%) or 0.129 mol/l (3.8%). The
choice of the concentration depends on the policy of the laboratories. The
mixing ratio is 1 part citrate solution to 9 parts blood.
Code | Vol(ml) | Size(mm) | Additives | Packing Q'ty |
---|---|---|---|---|
301105 | 1.8 | 13 x 75 | Sodium Citrate (0.109M, 3.2%)[Double Layer] | 1,000pcs/Box |
302105 | 2.7 | 13 x 75 | Sodium Citrate (0.109M, 3.2%)[Double Layer] | 1,000pcs/Box |
303105 | 3.6 | 13 x 75 | Sodium Citrate (0.109M, 3.2%)[Single Layer] | 1,000pcs/Box |
304205 | 4.5 | 13 x 100 | Sodium Citrate (0.109M, 3.2%)[Single Layer] | 1,000pcs/Box |
301112 | 1.8 | 13 x 75 | Sodium Citrate (0.109M, 3.8%)[Double Layer] | 1,000pcs/Box |
302112 | 2.7 | 13 x 75 | Sodium Citrate (0.109M, 3.8%)[Double Layer] | 1,000pcs/Box |
303112 | 3.6 | 13 x 75 | Sodium Citrate (0.109M, 3.8%)[Single Layer] | 1,000pcs/Box |
304212 | 4.5 | 13 x 100 | Sodium Citrate (0.109M, 3.8%)[Single Layer] | 1,000pcs/Box |

Plasma Tube
Features of Products
AMPULAB Plasma tubes are coated with lithium heparin or sodium heparin to inhibit clotting. Heparin activates antithrombin, thus blocking the coagulation cascade and producing a whole blood/plasma sample instead of clotted blood and serum. Lithium determination should not be performed in lithium heparin tubes. Samples collected in these tubes are used for plasma determinations in chemistry.
Code | Vol(ml) | Size(mm) | Additives | Packing Q'ty |
---|---|---|---|---|
404106 | 4 | 13 x 75 | Lithium Heparin 64 Unit | 1,000pcs/Box |
406206 | 6 | 13 x 100 | Lithium Heparin 96 Unit | 1,000pcs/Box |
400306 | 10 | 16 x 100 | Lithium Heparin 144 Unit | 1,000pcs/Box |
404107 | 4 | 13 x 75 | Sodium Heparin 64 Unit | 1,000pcs/Box |
406207 | 6 | 13 x 100 | Sodium Heparin 96 Unit | 1,000pcs/Box |
400307 | 10 | 16 x 100 | Sodium Heparin 144 Unit | 1,000pcs/Box |

PSGT (Plasma Seperation Gel Tube)
Features of Products
AMPULAB Plasma tubes with gel contain spray-coated lithium heparin and a polymer gel in the bottom for plasma separation. The specific gravity of this material can make the barrier gel move upward to the plasma – clot interface during centrifugation and it forms a stable barrier separating the plasma from cells. Samples processed in these tubes are used for plasma determinations in chemistry. Those tubes provide the convenience of gel separation with the added advantage of improved turnaround time.
Code | Vol(ml) | Size(mm) | Additives | Packing Q'ty |
---|---|---|---|---|
403108 | 3.5 | 13 x 75 | Gel / Lithium Heparin 64 Unit | 1,000pcs/Box |
404208 | 4.5 | 13 x 100 | Gel / Lithium Heparin 96 Unit | 1,000pcs/Box |
408308 | 8 | 16 x 100 | Gel / Lithium Heparin 144 Unit | 1,000pcs/Box |

Glucose Preservation Tube
Features of Products
AMPULAB Glucose tubes are ideal for glucose determinations. The tubes contain an anticoagulant and a stabilizer (EDTA and Sodium Fluoride / Potassium Oxalate and Sodium Fluoride). AMPULAB glucose tubes are used for the analysis of blood sugar and lactate.
Code | Vol(ml) | Size(mm) | Additives | Packing Q'ty |
---|---|---|---|---|
503109 | 3 | 13x75 | NaF 9mg / Pot. Oxalate 6mg | 1,000pcs/Box |
503110 | 3 | 13x75 | NaF 9mg / K3-EDTA 4.8mg | 1,000pcs/Box |

ESR Tube
Features of Products
AMPULAB ESR tubes contain 3.8% buffered tri-sodium citrate solution (0.129mol/l) and are provided in specially designated plastic tube for gamma irradiated sterilization. These tubes can be used for suspicious inflammatory reaction and development. The mixing ratio is 1 part citrate to 4 parts blood.
Code | Vol(ml) | Size(mm) | Additives | Packing Q'ty |
---|---|---|---|---|
601111 | 1.6 | 13 x 75 | Sodium Citrate (0.129M, 3.8%) | 1,000pcs/Box |
602111 | 2.4 | 13 x 75 | Sodium Citrate (0.129M, 3.8%) | 1,000pcs/Box |

EDTA Separation Gel Tube(ESGT)
Features of Products
AMPULAB ESGT tubes are EDTA with Gel and K2-EDTA which has a concentration of 1.8mg EDTA per 1ml blood. The Gel moves upward to Plasma-Blood cell interface forming a stable separating barrier during centrifugation. The plasma may be aspired directly from the collection tube eliminating the need for manual transfer to another container. and NAT tubes must be inverted 8 – 10 times to assure complete mixing with blood.
Code | Vol(ml) | Size(mm) | Additives | Packing Q'ty |
---|---|---|---|---|
703114 | 3.5 | 13 x 75 | K2 EDTA 6.3mg with Gel | 1,000pcs/Box |
705214 | 5.0 | 13 x 100 | K2 EDTA 9.0mg with Gel | 1,000pcs/Box |
708314 | 8.5 | 16 x 100 | K2 EDTA 15.3mg with Gel | 1,000pcs/Box |
Catalog
Download CatalogThe Features of 
Ampulab is evacuated blood collection system that qualified CE mark through strict manufacturing process and quality control, so basically, you can get reliable result in hormone, TDM, Latex analysis as well as clinical chemistry, hematology and immunology analysis.
- You can have very dependable result with Ampulab that has size and material that NCCLS recommends.
- You can use in any clinical experiment conveniently with all kind of blood collection tube for any clinical analysis.
- Ampulab is manufactured for easy work by marking the exact blood quantity on tube label.
- Improved process helps Ampulab for the best vacuum state and additives quantity.
- We minimize any variation during manufacturing by the automation of all process.
- Safety cap helps you from any infection and contamination during blood collection.
- The unbreakable plastic tube of PET material helps your safety for collecting, carrying, storing blood.
- Double Layer tube provides more accurate data.(Coagulation tube)
- We have own gamma sterilization facility FDA certified.
- Ampulab's tube dimension is optimized for all instrument including TLA system.
- Ampulab has a compact package for delivery and storage.


SSGT(Serum Separation Gel Tube) User Manual
STEP 01

Draw blood as specified volume
STEP 02

After drawing blood into tubes, surely make tubes inversion at least 8~10 times for good reaction of blood and clot activator.
STEP 03

After inversion, keep tubes on the rack at least 30 min for clotting
STEP 04

Keep centrifugation speed 1,800~2,000 RCF(G) for 10 min
STEP 05

After centrifugation, the horizontal gel-barrier is the best for data
How to Use
STEP 01

Prepare all material for blood collection, and decap multi-needle.
STEP 02

Fix multi-needle to the holder
STEP 03

Select a site for venipuncture and clean it with the alcohol swab to keep sterile. After drying alcohol, hold the needle with its slanting surface of skin.
STEP 04

During injection, inject a tube on the other side of multi-needle. The patient’s arm should be downward at this time and release tourniquet while flowing blood.
STEP 05

Finishing blood collection for one tube, remove the tube and put other tube into multi-needle. The holder and multi-needle should be fixed at this time.
STEP 06

Remove multi-needle from skin when finishing blood collection work, and stop bleeding with alcohol swab.
Caution in Use
Before Use
- You should not fasten tourniquet too tightly (about 100mmHg), and don't collect blood when fastening tourniquet more than 1 min.
- Deinfect the venipuncture part with alcohol swab, and inject after drying the skin.
- The elbow should be placed on cushion, and headed downward.
In Use
- During vein injection, hold needle 10-20 degree above the skin, and be careful not to penetrate the wall of vein.
- When replacing the tube, fix it with one hand not to move the needle.
- During blood collection, be careful not to touch additives to tube cap or multi-needle.
- When removing needle from vein, be careful not to hurt it, and cover alcohol swab against blood contamination.
After Use
- All tubes that have blood afer collection should be shaked about 8 times up and down. (Coagulation tube is 4 times)
- Every tube should be applied to proper centrifugation.
- Be careful about hemolysis.
The Procedure of Blood Collection
Use from non-additives tube.
- 01No Additive
- 02Coagulation
- 03Serum(Gel)
- 04Heparin(Gel)
- 05EDTA
- 06Glucose
- 07The others
Color Chart
Color | Total Volume(ml) | 1 | 1.6 | 1.8 | 2 | 2.4 | 2.7 | 3 | 3.5 | 3.6 | 4 | 4.5 | 5 | 6 | 8 | 8.5 | 10 | Additives |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tube size(mm) | 13*75 | 13*75 | 13*75 | 13*75 | 13*75 | 13*75 | 13*75 | 13*75 | 13*75 | 13*100 | 13*100 | 13*100 | 13*100 | 16*100 | 16*100 | 16*100 | ||
![]() |
Serum | ○ | ○ | ○ | Clot activator | |||||||||||||
![]() |
Serum(Gel) | ○ | ○ | ○ | Clot activator + Separation Gel | |||||||||||||
![]() |
Haematology | ○ | ○ | ○ | ○ | ○ | ○ | K3EDTA / K2EDTA | ||||||||||
![]() |
Coagulation | ○ | ○ | ○ | ○ | Trisodium Citrate 0.129M 9:1, 3.8% / Trisodium Citrate 0.109M 9:1 3.2% | ||||||||||||
![]() |
Plasma | ○ | ○ | ○ | Lithium Heparin, Sodium Heparin | |||||||||||||
![]() |
Plasma(Gel) | ○ | ○ | ○ | Lithium Heparin + Separation Gel | |||||||||||||
![]() |
Glucose | ○ | Sodium Fluoride + Potassium oxalate | |||||||||||||||
![]() |
ESR | ○ | ○ | Trisodium Citrate 0.129M 4:1, 3.8% | ||||||||||||||
![]() |
ESGT | ○ | ○ | ○ | K2 EDTA with Gel |
Centrifugation for tube type
Tube Type | Centifuge speed(g) | Time(min) | |
---|---|---|---|
Serum | Plain | 1500~1600 | 10 |
Gel | 1800~2000 | 10 | |
Plasma | Heparin | 2000~2500 | 15 |
Gel | 2200~2300 | 15 |
※ Centrifuge can be influential the component of gel barrier. Swing-out rotor centrifuge instrument can work more gel barrier.
Gel barrier work should be at room temperature (15.24C).
Troubleshooting Guide
IF AN INCOMPLETE COLLECTION OR NO BLOOD IS OBTAINED
- Change the position of the needle. Move it forward it may not be in the lumen).
- or move it backward (it may have penetrated too far).
- Adjust the angle (the bevel may be against the vein wall).
- Loosen the tourniquet. It may be obstructing blood flow.
- Try another tube. There may be no vacuum in the one being used.
- Re-anchor the vein. Veins sometimes roll away from the point of the needle and puncture site.
IF BLOOD STOPS FLOWING INTO THE TUBE
- The vein may have collapsed; resecure the tourniquet to increase venous filling. If this is not successful, remove the this is not successful, remove the needle, take care of the puncture site, and redraw.
- The needle may have pulled out of the vein when switching tubes. Hold equipment firmly and place fingers against patient's arm, using the flange for leverage when withdrawing and inserting tubes.
PROBLEMS OTHER THAN AN INCOMPLETE COLLECTION
- A hematoma forms under the skin adjacent to the puncture site - release the tourniquet immediately and withdraw theneedle. Apply firm pressure.
- Hematoma formation is a problem in older patients.
- The blood is bright red (arterial) rather than venous. Apply firm pressure for more than 5 minutes.
We, Soyagreentec Co., Ltd. , acquired ISO9001, ISO13485 and CE certificate through the thorough quality control process and inspection.